CATALOGO DE COMPRESORES DANFOSS PDF

Application guidelines. Maneurop® reciprocating compressors. MT / MTZ. 50 – 60 Hz – R22 – RA – RA/C/F – Ra. Danfoss Commercial Compressors Online Datasheet Generator . instalación y aplicación de para compresores Maneurop MT, MTZ y LTZ. Guías de Aplicación . 5 Danfoss does not authorise the use of hydrocarbons in Maneurop® MT/MTZ The Maneurop® MT compressor is de-.

Author: Shakak Mashicage
Country: Tanzania
Language: English (Spanish)
Genre: Technology
Published (Last): 13 November 2012
Pages: 481
PDF File Size: 5.80 Mb
ePub File Size: 12.40 Mb
ISBN: 138-4-38807-435-8
Downloads: 94866
Price: Free* [*Free Regsitration Required]
Uploader: Mezigar

All compressors have a green label with the typedesignation. This starting device is normally used in well-designed refrigeratingsystems with capillary tube as throttling device. Performer Compresores scroll Sencillos, 20 a kW 50 – 60 Hzweb. This can be done by using well-dimensioned condenser surfaces and by ensuringgood ventilation around ckmpresores compressor under all operating conditions.

Compresores Danfoss Para 134a

El controlador de temperatura seria un STC At stable operation conditions the condensing temperature must not exceed F 60C. The code numbers for the mounting accessories are specified in the individualcompressor datasheets.

Fallaselectronicas — Juan Luis buenas mi estimado amigo saludos desde Venezuela tengo un compresor marca kulthorn c bel2z, lra The design of the electrical equipmentdepends on the actual compressor design. Electricalcomponents are packed in separate boxes.

El gas que vi que usan es ra. Compressors with denominations ending with FX are F-types designed for low evaporationtemperatures with HST starting characteristics expansion valve.

  HANDROANTHUS CHRYSOTRICHUS PDF

The refrigerant amount may be critical as regards oil foaming and liquid hammer after longstandstill periods. Compressors with denominations ending with G are primarily designed for high evaporationtemperatures HBP High Back Pressure for use in liquid coolers, dehumidifiers, dantoss counters, vending machines and similar applications.

LFFEThe first line states the model designation and the code no.

ECL Comfort 210

This starting compreosres is mandatory for some compressor designs and itis an option for others specified in the invidual data sheets. This starting device requires a pressure-equalized sys-tem before each start. The design of the electrical equipment dependson the actual compressor design. Compressors with denominations ending with FT are F-types designed for low evaporationtemperatures LBP Low Back Pressure for use in refrigerators, freezers and similar applica-tions operating in regions with unstable supply voltage.

Fallaselectronicas – Juan Luis. Compresores Para Una Minera Documents. Como calcular hp compresor de nevera was last modified: The oil charge is specified in the individual datasheets.

Compresores Danfoss Para a

This label has a blue stripe and thetext Ra. Compressors with denominations ending with FK are F-types designed for low evaporationtemperatures with LST starting characteristics capillary tube. Compressors for Refrigeration and Air ConditioningA wide range of hermetic reciprocating compressors and scroll compressors aswell as aircooled condensing units.

  LIFE CYCLE OF AMELOBLAST PDF

As shown in the drawings the following designs ofstarting devices exist: Buenas tardes Gracias Alfredo. These limitations secure compresoress of valves, gaskets, oil, and motor insulation1. Condition at delivery12 Catalovo. Anti-freeze agents must not be used in the compressors as such agents are damaging toseveral of the materials used.

On some compressorproduction lines the stamping has been changed to needle printing into the side of the housing. Quantities per pallets are specified in the individual datasheets. The compressors use polyolester oils and are approved only for these oils and Ra.

Moisture andImpuritiesJuly CK. Tambien se me ocurrio lo siguiente: Estimados muy buenas …. The windingtemperature must not exceed F C.

The design of the electrical equipment depends on the actual compressor design. El tipo Danfossson compresores que mirando de arriba, son redondos. The recommandations must be regarded as a guideline only as they presuppose a properdimensioning of the refrigeration system.

The compressors can be supplied with the following motor systems: Compressors for heating pumpsystems. Instead place thecompressor on its side with the connectors caatalogo. La marca es Tecumseh.